二手 AGILENT / HP / HEWLETT-PACKARD / KEYSIGHT 8563E #9014804 待售

ID: 9014804
Spectrum analyzer Model number: 8565e Options: 006, 007, 008, 8ze Option description: Opt. 006: 30 hz to freq. Coverage Opt. 007: digitized fast time-domain sweeps Opt. 008: signal identification Key features: Continuous 30 hz to 26.5 ghz sweeps Resolution bandwidths of 1 hz to 100 hz digitally implemented for measurement speed Precision timebase and 1 hz counter resolution Adjacent channel power, channel power, carrier power and grated video measurements standard Mil-t-28800 rugged Frequency specifications: Frequency range (internal mixing): 9 khz to 26.5 ghz; 30 hz to 26.5 ghz (option 006) Frequency range (external mixing): 18 ghz to 325 ghz in 12-wave guide bands Frequency reference accuracy: Temperature stability: ±1 x 10-6 Aging (per year): ±1 x 10-7 Setability: ±1 x 10-8 Warmup (nominal): 5 minute ±1 x 10-7; 15 minute ±1 x 10 -8 Frequency readout accuracy (n = l0 harmonic): Span > 2 mhz x n: ±(freq. Readout x freq. Ref. Accuracy + 5% x span + 15% x rbw + 10 hz) Span < or = to 2 mhz x n: ±(freq. Readout x freq. Ref. Accuracy +1% x span +15% x rbw + 10 hz) Marker count accuracy (s/n > or = to 25 db): ± (marker freq. X freq. Ref. Accuracy + 2 hz x n + 1 lsd) Counter resolution: selectable from 1 hz to 1 mhz Frequency span: Range: 0 hz, 100 hz to maximum frequency Sweep time: Range: Span = 0 hz: 50 µs to 6,000 s Span > or = to 100 hz: 50 ms to 100 ks Accuracy: Sweep time > 30 ms: ±1% digital Sweep time < 30 ms: ±10% analog; ±0.1% digital (option 007) Sweep trigger: delayed, free run, single, line, video, external Resolution bandwidth: Range (-3 db): 1 hz to 1 mhz in a 1, 3, 10 sequence and 2 mhz Accuracy: 1 hz to 300 khz: ±10% 1 mhz: ± 25% 2 mhz: +50%, -25% Selectivity (-60 db/-3 db): Rbw > or = to 300 hz: < 15:1 Rbw < or = to 100 hz: < 5:1 Video bandwidth range: 1 hz to 3 mhz in a 1, 3, 10 sequence Noise sidebands (center frequency < or = to 1 ghz): 100 hz offset: < -18 dbc/hz 1 khz offset: < -97 dbc/hz 10 khz offset: < -113 dbc/hz 100 khz offset: < -117 dbc/hz Residual fm (zero span): < 1 hz p-p in 20 ms; < 0.25 hz p-p in 20 ms (nominal) Amplitude specifications: Range: displayed average noise level to +30 dbm Maximum safe input level: Average continuous power: +30 dbm (1w, input atten. > or = to 10 db) Peak pulse power (< 10 µs pulse width and < 1% duty cycle): +50 dbm (100 w, input atten. > or = to 30 db) Dc volts: < ±0.2 v (dc-coupled) 1 db gain compression: 10 mhz to 2.9 ghz: mixer level < or = to -5 dbm 2.9 ghz to 6.5 ghz: mixer level < or = to 0 dbm > 6.5 ghz: < or = to -3 dbm Displayed average noise level (0 db input atten., 1 hz rbw1): 30 hz frequency: -90 dbm 1 khz frequency: -105 dbm 10 khz frequency: -120 dbm 100 khz frequency: -120 dbm 1 to 10 mhz frequency: -140 dbm 10 mhz to 2.9 ghz frequency: -149 dbm 2.9 to 6.5 ghz frequency: -148 dbm 6.5 to 13.2 ghz frequency: -145 dbm 13.2 to 22.0 ghz frequency: -149 dbm 22.0 to 26.5 ghz frequency: -139 dbm Notes: 10 hz rbw (min. Rbw with option 103) add 10 db to noise floor Hp 8561e only Hp 8565e only Hp 8563e/64e/65e only Hp 8563e only Hp 8564e/65e only Except hp 8561e For hp 8561e: -145 dbm Toi reference to single tone Residual responses (>200 khz, n=1): <-90 dbm Display: Viewing area: approx. 7 cm (v) x 9 cm (h) Scale calibration: 10 x 10 divisions Log scale: 10, 5, 2, 1 db per division Linear scale: 10% of ref. Level per division Display scale fidelity: Log: ±0.1 db/db to a maximum of ±0.85 db, 0 to -90 db; maximum of ±1.5 db, 0 to -100 db (rbw < or = to 100 hz) Linear: ±3% of reference level Reference level range: log = -120 to +30 dbm in 0.1 db steps; linear = 2.2 µv to 7.07 v in 1% steps Frequency response, relative (10 db input attenuation): Frequency: 100 mhz to 2.0 ghz: ±1.0 db 30 hz to 2.9 ghz: ±1.25 db 2.9 ghz to 6.5 ghz: ±1.5 db 6.5 ghz to 13.2 ghz: ±2.2 db 13.2 ghz to 22.0 ghz: ±2.5 db 22.0 ghz to 26.5 ghz: ±3.3 db Calibrator output: 300 mhz x (1 ±freq. Ref. Acc'y), -10 dbm: < ±0.3 db Input attenuator: Range: 0 to 70 db in 10 db steps Switching uncertainty (ref. To 10 db, 30 hz to 2.9 ghz): < ±0.6 db/10 db step, ±1.8 db max. Repeatability: ±0.1 db (nominal) If gain uncertainty (10 db atten., 0 to -80 dbm ref. Level): < ±1 db Resolution bandwidth switching uncertainty: < ±0.5 db Pulse digitization uncertainty (pulse response mode, prf > or = to 720/sweep time, rbw < or = to 1 mhz): < 1.25 db pk-pk (log); 4% of reference level pk-pk (linear) Accuracy (from gate trigger input to pos. Edge of gate output): < ±1 µs Gate length: Range: 1 µs to 65.535 µs Resolution: 1 µs Accuracy (from pos. Edge to neg. Edge of gate output): < ±1 µs Delayed sweep specifications: Trigger modes: free run, line, external, video Range: 2 µs to 65.535 µs, option 007, sweeptime < 30 µs; -9.9 µs to +65.535 µs; sweeptime > or = to 30 µs, +2 µs to 65.535 µs Resolution: 1 µs Accuracy: ±1 µs Demodulation (spectrum) specifications: Modulation type: am and fm Audio output: speaker and phone jack with volume control Inputs and outputs (all values nominal) specifications: Front panel connectors: Rf input (50 ω): type-n female Vswr (> or = to 10 db atten.): < 1.5:1 below 2.9 ghz; < 2.3:1 > or = to 2.9 ghz Lo emission level (average with 10 db atten): < - 80 dbm Second if input (sma female, 50 ω): Frequency: 310.7 mhzfull screen level: -30 dbm Gain compression: -20 dbm First lo output (sma female, 50 ω): Frequency: 3.0 to 6.8107 ghz Amplitude: +16.5 dbm ±2 db Cal output: bnc female, 50 ω Probe power: +15 vdc, -12.6 vdc, and gnd (150 ma maximum each) Rear panel connectors: 10 mhz reference in/out (shared bnc female, 50 ω): Output frequency accuracy: 10 mhz ±(10 x mhz freq. Ref. Acc'y) Output amplitude: 0 dbm Input amplitude: -2 to +10 dbm Video output (bnc, 50 ω): Amplitude (rbw > or = to 300 hz): 0 to +1 v full scale Lo sweep i fav output (shared bnc female, 2 kω): Amplitude (lo sweep): 0 to 10 v, no load Blanking/gate output: shared bnc female, 50 ω, ttl output External/gate trigger input (shared bnc female, > 10 kω): settable to high ttl or low ttl Hp-ib: ieee-488 bus connector Interface functions: sh1, ah1, t6, l4, sr1, rl1, pp0, dc1, dt0, c1, c28, e1 General specifications: Environmental: Military specs: per mil-t-28800 Calibration interval: two years Warmup time: 5 minutes in ambient conditions Temperature: -10°c to +55°c (operating); -51° to +71°c (non operating) Humidity: 95% @ 40°c for five days Rain resistance: drip-proof at 16 liters/hour/sq. Ft. Altitude: 15,000 ft. (operating); 50,000 ft. (non operating) Pulse shock (half sine): 30 g for 11 ms duration Transit drop: 8-inch drop on six faces and eight corners Electromagnetic compatibility: conducted and radiated interference in compliance with cispr pub. 11 (1990). Meets mil-std-461c, part 4, with certain exceptions. Power requirements: 115 vac operation: 90 to 140 v rms, 3.2 a rms max., 47 to 440 hz 230 vac operation: 180 to 250 v rms, 1.8 a rms max., 47 to 66 hz Maximum power dissipation: 180 w Audible noise (nominal): < 5.0 bels power at room temp. (iso dp7779) Size (w/o handle, feet, cover): 337 mm w x 187 mm h x 460 mm d (13 1/4" x 7 3/8" x 18 1/8") Weight (carrying, nominal): 20 kg (44 lb).
AGILENT/HP/HEWLETT-PACKARD/KEYSIGHT 8563E是一款功能强大的电子测试和测量设备,旨在满足设计和制造工程师的需求。它采用频谱分析仪和网络分析仪在一台仪器中的高清晰度组合,能够对模拟、数字和射频电路进行精确分析和故障排除。HP 8563E的15.6英寸高清显示屏提供精确的清晰度,使其更易于与常用的测试和测量应用程序配合使用。AGILENT 8563E非常适合需要从单一仪器获得多种功能的用户。它具有标准的10 Hz至3.6 GHz频率范围,能够测量各种参数,包括直流(DC)参数、频率响应和虚假信号。KEYSIGHT 8563E还配备了噪声数字、谐波分析、返回损耗、阻抗测量等强大的分析能力。这使得它成为应用程序(包括EMC、光学、音频和视频测试)的通用工具。HEWLETT-PACKARD 8563E的最大扫描速度为10毫秒,为大多数应用程序提供了所需的速度和准确性。它还包括各种有效操作的有用功能,如多语言显示,以及内置的方程求解和数学包。此外,8563E还配备了一套全面的自动化测试,可根据生产测试中的特定限制快速验证设备操作。这允许用户节省时间并简化测试过程。AGILENT/HP/HEWLETT-PACKARD/KEYSIGHT 8563E设计为易于集成到自动化测试系统和生产线中,并且与LabView软件包兼容。HP 8563E是一种可靠可靠的测试和测量设备.它在单个+5V直流电源上运行,在屏蔽和静电放电方面满足大多数MIL-STD。此外,它还符合安全、电磁兼容性和射频辐射防护所需的UL和CE标准。AGILENT 8563E是设计、开发和制造团队的强大而可靠的电子测试和测量设备解决方桉。15.6英寸高清显示屏、多功能分析功能、自动化测试和易于集成,使其成为各种应用程序的绝佳选择。
还没有评论