二手 HODGE 2116 #179900 待售
网址复制成功!
ID: 179900
Autoclave
60” ID x 12ft Long Autoclave Vessel
48” ID x 8ft Long Work Area
Maximum Design Pressure: 100 PSIG
Pressure Rate: 0-10 PSI/Minute Average
Depressurization Rate: 0-10 PSI/ Min. Average based on load
Pressure Control Accuracy: +/- 1 PSI
Pressure components:
Inlet and Exhaust Valve
Pressure Transducer
Monitoring and Data Acquisition
Temperature:
Maximum Design Temperature: 500°F
Heating Rate: 0-10°F/Min based on air temperature and autoclave load
Cooling Rate: 10°F/Min based on average air temperature and autoclave load from maximum working temperature to 150°F
Customer must have cool water
Temperature Control Accuracy and Uniformity: +/- 5°
Door accessories:
Door Safety Limit Switch
Door Seal
Hydraulically Operated
Insulation Liner and 3” of Insulation
Insulation:
The interior of the autoclave will be insulated with 3” of high temp insulation
The insulation will then be covered by aluminized sheet metal
All exposed surfaces will be painted with industrial enamel
The autoclave will meet OSHA hot surface guidelines
Exterior:
Painted with heat and corrosion resistant primer and paint
Temperature Monitoring Devices:
(12) Thermocouples included
Cooling System:
Modular cooling coil located in front of electric coil
Cooling water supplied by others
Requires cooling water equivalent to a 21 ton cooling tower to achieve 6 Deg. F. per minute cool down
Cooling tower available
Vacuum System:
Vacuum manifold included
Vacuum Pump included
(5) Vacuum lines included
Chamber Pressure:
Chamber Pressure controls for air or nitrogen with data collection included.
Compressed nitrogen provided by others
Controls:
Windows based Industrial PC Programmable Control System using Phoenix Logic Ethernet for autoclave with the following features: (with no manual overrides)
Control heating ambient – 450 Deg. F. at 0-10 Deg/Min F. Loaded based on 1,000 lb. of steel tooling and 1,000 lb composite product load.
Run at precise temperature ambient – 450 Deg. F. for programmed time period
Total automatic control of cycle sequences from beginning to end
Operator controls for locking door. 1.5 PSI Door Interlock
Process complete and ready to open door indicator lights
Temperature and Pressure safety back ups
Full program editing and storage capabilities
Remote monitoring of the system is available by Ethernet Connection
Thermocouples quoted separately
Vacuum Lines quoted separately
Tracks:
Track support and angle iron tracks provided. The tracks will be able to handle the customer supplied cart
Cart is available at an additional cost
Valves:
Safety relief
One Pressure transducer for controlling pressure
Pressure switch for high pressure alarm
Safety:
Man in cave safety switch
Optional:
Vacuum Line with:
Two motorized ball valves
Transducer with data collection
Manual ball valve
Pressure gauge
Three way ball valve for transducer calibration
Optional:
Thermocouple jacks with data acquisition
2 HP vacuum pump
25 Ton cooling tower with controls, pump storage and storage tank.
HODGE 2116是一个环境室,专门设计用于测试各种材料在不同气候下的耐久性和反应。该实验室设备用于精确模拟封闭区域内的变化温度、相对湿度和气压。腔室的温度范围为-60°C至+150°C,温度均匀度± 0.5°C,温度均匀度稳定性为0.2°C。其相对湿度范围从0到95%不等。该装置使用蒸发传热来控制温度和湿度。其专利设计有一个带有特殊过滤器的排气系统,使室内产生的大气以及室外的环境不受影响。此外,该腔室还配备了数字控制器,可以让用户设定精确的条件,便于管理腔室内部的环境设置。2116提供了一个可编程计时器,允许在广泛的温度和湿度水平上进行长期测试。该室还拥有两个用于测量温度的热电偶,一个在控制柜中,一个在调节柜中,提供实时温度读数。此外,腔室的顶级智能控制器允许精确和可重复的测试设置,确保测试条件保持一致和可靠。HODGE 2116坚固的结构和车架设计最大的刚性和耐用性,采用不锈钢内墙,能承受恶劣的条件,持续更长的测试时间。该室的独一无二的精密密封系统提供防漏防尘绝缘。此环境室可降低噪声水平并提供最佳冷却效果,非常适合需要近乎静音操作的应用。此外,2116的设计采用了紧凑和可运输的外形规格,使其能够适应任何标准的实验室空间,并便于实验室之间的移动。通过易于使用的控制,腔室使故障排除和维护变得容易和高效。总而言之,HODGE 2116环境室是一种专门设计的仪器,经过专业设计,考虑到耐用性和精确度,非常适合各种材料测试应用。