二手 BROOKS / PRI AUTOMATION SENTRY 1510 #165511 待售
网址复制成功!
单击可缩放
ID: 165511
Manual Process Pressure Control System, Part Number: 11911G01 Rev. F
Features:
Sealed system
Air-flow regulation with millisecond response time
Automatic set point control
Analog or digital host communication
Production-proven
Specifications:
Type: Manual
Style: Horizontal Mount.
Negative Pressure Configuration: -0.12" to -1.85" of water column. (-3 mm to -47 mm to water column.)
Positive Pressure Configuration: +0.12" to +1.85" of water column. (+3 mm to +47 mm of water column.)
Flow Range: 0.01 to 1.05 SCFM (0.3 to 30 LPM)
Accuracy to Set Point: ±0.04" of water column. (±1.0 mm of water column.) for dry process, ±0.08" of water column. (±2.0 mm of water column.) for pyrogenic processes
Response Time: 50 milliseconds to exhaust fluctuations of 100%. Response to pyrogenic ignition or extinguish will vary by installation.
Materials: Ryton and Teflon with Viton elastomers
Set Point Control: 0-5 volt analog, RS422/RS485 at 9600 baud, Stand alone operator keypad (I do not believe it has this option)
Power Requirements:
TIM (Supervisor): +15 to +24 VDC, 650 mA and -15 to -24 VDC, 50 mA (I don't believe it has this option)
Power Supply: 90 - 260 VAC, 47-63 Hz, 12 W nominal
Facilities Requirements:
Minimum House Exhaust: Negative pressure configuration 0.4" w.c. (10 mm w.c.) more negative than set point, Positive pressure configuration -0.5" w.c. (-13 mm w.c.)
Maximum House Exhaust: 5.0" of water column (125 mm of water column.)
Nitrogen:
Input Tube OD: .25"
Minimum Pressure: 40 psig (2.8 Kg/cm2)
Maximum Pressure: 100 psig (7.0 Kg/cm2)
Minimum Grade: House grade or better
Input and Output Connections: 1" female NPT.