二手 NIKON NSR SF200 #9222705 待售

NIKON NSR SF200
ID: 9222705
晶圆大小: 8"-12"
KrF Stepper, 8"-12" Minicomputer system Liquid crystal monitor Operational panel Stage controller Alignment controller Panel controller Lens controller Wafer loader controller Reticle loader controller S/G Conversion unit Signal monitor unit Stage power amplifier Reduction projection optical system: Reduction ratio: 1/4 N.A: 0.50 - 0.63 (Variable) Lens distortion: ≦±20 nm (Including magnification error) Exposure area: 26 mm x 33 mm Exposure wavelength: KrF Excimer laser (248nm) Wavelength stability: ±0.10 μm Spectral bandwidth (FWHM): ≦0.8 μm Illumination optical system: Maximum exposure frequency: 2000 Hz Illumination uniformity: ≦±1.0% Integrated exposure accuracy: ±1.3% Integrated exposure matching: ±1.2% Dose setting range: 1mJ/cm2-1J/cm2 & 0 Coherency factor: 0.3-0.8 (Lens NA 0.63) Auto reticle blind system: Blind configuration: Focused type Minimum blind setting range: 2.0 mm x 2.0 mm Setting accuracy: +0.4 mm to +0.8 mm Reticle interferometer system: Configuration: Three axes (X, Y, θ) Interferometer minimum reading unit: 1.2 nm Reticle table: Configuration: Three axes (X, Y, θ) Stroke: ≧±1.1 mm for each axis Angle of rotation: ±1° Reticle holder: 6" Position control: Closed-loop servo control Reticle alignment system: Reticle loading: Automatic from reticle loader Alignment method: Bright-field off-axis under Broadband illumination TV image processing Observation system: Display on ITV monitor Field image alignment (FIA) system: Observation system: 79x / 490x Functions: Fine alignment Search alignment Visual observation during manual assist mode Auto focus system: Detection method: Broadband light detection (Multi point sensor) Repeatability: ±100 nm Vertical stroke: 0.6 mm Focus offset input range: ±10 μm Auto focus tracking range: ±0.3 mm Auto focus spot: Maximum 9 points selected from total 29 points Auto leveling system: Detection method: Broadband light detection method (2 Dimension multi point sensor) Target plane: Image plane of projection lens Accuracy: ±1.5 sec (Relative to the target plane) Repeatability: ±1.0 sec Leveling offset input: ±10 sec Amendable tilt: 2.6 minutes (Relative to wafer backside) Wafer interferometer system: Configuration: Five axes (X1, X2, X3, Y1, Y2) Minimum reading unit: 0.6 nm Each axis Laser wavelength correction: Automatic Wafer X-Y stage: Stroke: ≧300 mm in X and Y directions Positioning control: Closed-loop servo control Using laser interferometer Stepping precision: 18 nm Array orthogonality: ≦±0.1” (After correction by software) Wafer table: Wafer table rotation angle: ±1° Wafer holder: 300 mm / 200 mm Reticle loader: Storage capacity: Standard 10 Reticle: Size: 6 x 6 Thickness: 0.25" Material: Quartz glass Type: Low-reflective chromium mask (Single-layer chromium) Options: Test reticle Extended wafer carrier table On-line application Laser step alignment (LSA) Lithography information control system (LINCS) Reticle bar-code reader Extended reticle library FU PPD R.E.T (Resolution enhancement technology) Power change (Correspondence high sensitivity resist with ND filter).
NIKON NSR SF200 Wafer Stepper是一种先进的半导体光刻设备,可以提供严密的工艺控制和精度,以生产高质量的半导体产品。NIKON NSR SF 200专为大批量生产而设计,可提供高级性能,满足多个项目的严格要求。该系统设计用于处理多种基材,包括硅片、金属板和石英封装。NSR SF200是一个多光束单元,能够同时处理多达16次曝光。这种高度并行的功能既具有内置激光机器,又具有定制设计的静电微镜阵列,有助于提高性能并显着缩短生产时间。此外,该工具还包括确保晶片精确对准的高级光学模块。这是通过精细的光学跟踪资产来实现的,该资产允许将基板精确分配给适当的光束。该型号配备了多种支持阵列、失真校正和掩码鉴定功能的图像处理工具。这些工具使设备能够处理分辨率较高的小阵列,包括用于高长宽比层的阵列。此外,该系统还提供各种先进的迭加优化技术,以提高任何晶圆尺寸上的迭加精度和均匀性。该单位配备了各种自动化能力,使他们能够运行无人操作。这包括自动校准机和作业调度工具。该软件还帮助工程师使用许多光学检查和模拟系统分析他们的晶片。NSR SF 200非常适合广泛的应用,包括MEMS、光电子和集成电路制造。资产具有多种功能和自动化功能,有助于提高生产效率和质量。它提供严格的过程控制,能够满足大型项目的严格要求。多波束模型和定制设计的静电微镜阵列使工程师能够在大批量生产中同时处理多个晶片,从而确保节省时间和成本。NIKON NSR具有令人印象深刻的一系列特性和功能,SF200成为生产高性能设备的强大而高效的工具。
还没有评论